Bewerbung

Member of AFRISO-EURO-INDEX-Group
Phone: +49 (0)7558 9206-0    
Mail: info@systronik.de    
  
Systronik

MULTILYZER® STx Industrial Set (O2, CO/H2-compensated, NO, SO2, draft, diff. pressure)

P00016

Professional and robust set for industrial combustion, emission and process monitoring including NOx and SO2 measurement.




Back


  • Flue gas analysis for all liquid, gaseous and solid fuels
  • Latest ECOx sensor technology with 5 years guarantee for O2 and CO cells
  • Features Bluetooth® and QR code data transmission to the EuroSoft® connect App
  • Extendable with CAPBs® units and high-quality accessories for all types of service measuring tasks
  • All-in-one: Flue gas analysis, (differential) pressure measurement, (differential) temperature measurement and air flow measurement

 

The MULTILYZER® STx Industrial Set perform accurate measurements of O2, CO/H2, NO, SO2, temperatures, pressure (draft) as well as precise calculation of various parameters such as lambda, combustion efficiency (Eta), flue gas loss (qA), dew point, NOx and SO2

 

Scope of delivery
M04744210 MULTILYZER® STx (O2, CO/H2, NO, SO2, P-D7, Bluetooth®)
511010 Option: Datenlogger
510921
Basic handle with draft, 2400 mm
523229
Interchangeable Probe 300 mm
523493
Power supply unit
523506
Charging cable
500141.1
Air sensor 80 mm
500216
Filter set
511035
microSD card 4 GB with card reader
511315 Case



O2 (oxygen)
Measuring range
0 to 21.0 vol.-%
Accuracy
±0.2 vol.-% RDG
Resolution
0.1 vol.-%
Response delay (t90)
< 30 seconds
CO (carbon monoxide) with H2-compensation
Measuring range
0 to 10,000 ppm
Accuracy
±5 ppm (< 50 ppm)
±5 % RDG (> 50 ppm)
Resolution
1 ppm
Response delay (t90)
< 60 seconds
CO2 (carbon dioxide) calculated
Measuring range
0 to CO2 max. (depending on fuel)
Accuracy
±0.2 vol.-%
Resolution
0.1 vol.-%
Response delay (t90)
< 30 seconds
Flue gas temperature
Measuring range
0 to 1,150 °C
Accuracy
±1 °C + 1 digit (< 300 °C)
±1 % RDG (> 300 °C)
Resolution
0.1 °C
Response delay (t90)
< 30 seconds
Ambient air temperature
Measuring range
-20 to 200 °C
Accuracy
±3 °C + 1 digit (-20 to 0 °C)
±1 °C + 1 digit (0.1 to 200 °C)
Resolution
0.1 °C
Response delay (t90)
< 30 seconds
Draft/differential pressure
Measuring range
±70 hPa (draft)
±150 hPa (diff. pressure)
Accuracy ±0.02 hPa (< 2.00 hPa)
±1 % RDG (> 2.00 hPa)
Resolution
0.01 hPa (< 20 hPa)
0.1 hPa (> 20 hPa)
Max. overload
1350 hPa
Response delay (t90)
< 10 seconds
Pitot
Measuring range
0.5 to 70 m/s
Accuracy
±0.8 m/s
Resolution
0.1 m/s
Response delay (t90)
< 20 seconds
Barometric pressure
Measuring range
500 to 1.150 hPa
Accuracy
±10 hPa
Resolution
1 hPa
Response delay (t90)
< 60 seconds
Option: CO2 (carbon dioxide)
Measuring range 0 to 20 vol.-%
Accuracy ±1 vol.-%
Resolution 0.1 vol.-%
Response delay (t90) < 60 seconds 
NO (nitrogen oxide)
Measuring range
0 to 5,000 ppm
Accuracy
±5 ppm (< 50 ppm)
±5 % RDG ( > 50 ppm)
Resolution
1 ppm
Response delay (t90)
< 60 seconds
Option: NO2 (nitrogen dioxide)
Measuring range
0 to 500 ppm
Accuracy
±10 ppm (< 50 ppm)
±10 % RDG (> 50 ppm)
± 5 ppm (< 100 ppm)1)   
± 5 % RDG (> 100 ppm)1) 
Resolution
0.1 ppm
Response delay (t90)
< 60 seconds / < 180 seconds1) 
SO2 (sulfur dioxide)
Measuring range
0 to 5,000 ppm
Accuracy
±10 ppm (< 200 ppm)
±5 % RDG (> 200 ppm)
±5 ppm (< 200 ppm)1) 
±5 % RDG (> 200 ppm)1) 
Resolution
1 ppm
Response delay (t90)
< 60 seconds / < 180 seconds1) 
Option: COhigh (carbon monoxide)
Measuring range
0 to 4.0 vol.-% (= 40,000 ppm)
Accuracy
±10 ppm
±5 % RDG
Resolution
0.001 vol.-%
Response delay (t90)
< 60 seconds
Option: NOlow (nitrogen oxide)
Measuring range
0 to 300 ppm
Accuracy
±2 ppm (< 40 ppm)
±10 % RDG (> 40 ppm)
Resolution
0.1 ppm
Response delay (t90)
< 60 seconds
Option: SO2x (sulfur dioxide)
Measuring range
0 to 2,000 ppm
Accuracy
±5 ppm (< 200 ppm)
±10 % RDG (> 200 ppm)
Resolution
0.1 ppm
Response delay (t90)
< 60 seconds / < 180 seconds1)

1) with extended flue gas treatment (e.g. MAXISYSTEM ST)


Set overview
 


 



Systronik

EuroSoft® connect for iOS and Android

The free EuroSoft® connect App allows to transmit measured values to iOS and Android smartphones or tablets via QR code or Bluetooth®.


to the product
Systronik

EuroSoft® connect for Windows

The EuroSoft® connect software allows you to transmit measured values to the PC via microSD card and control the instrument remote via Bluetooth®


to the product

Systronik

Combustion air sensor

80 mm, with magnet and cone


to the product
Systronik

MAXISYSTEM ST

The MAXISYSTEM ST portable gas treatment system is suitable for professional settings and control measurements for all small gas, oil and solid fuel systems. 


to the product
Systronik

Connection set for differential pressure measurement

Connection set for differential pressure measurement for handheld measuring instruments.


to the product
Systronik

EUROprinter II - Bluetooth® & IR

High-speed printer that supports both IR and Bluetooth® and features integrated magnets on the back


to the product
Systronik

EUROprinter II - IR

Compact infrared high speed thermal printer with magnets on the rear side


to the product
Systronik

Pitot probe 360 mm

For measuring flow velocities, e.g. in ventilation ducts or process air


to the product

Systronik

Filter package NOx/SOx

Filters do not absorb NO2 or SO2 molecules.


to the product












Our recommendations


Systronik

MAXISYSTEM ST

The MAXISYSTEM ST portable gas treatment system is suitable for professional settings and control measurements for all small gas, oil and solid fuel systems. 


to the product
Systronik

MULTILYZER® STx NOX Set (O2, CO/H2-compensated, NO, NO2, draft, diff. pressure)

Professional and high quality flue gas analyzer set for NOx measurements with separate NO and NO2 sensor combination.


to the product